KINGYEAR has successfully completed the production and inspection of a batch of 21% IACS Copper-Clad Steel (CCS) Strand customized for a customer in Turkmenistan.

The product combines the mechanical strength of steel with the electrical conductivity of copper, making copper-clad steel strand a practical solution for grounding, lightning protection, railway earthing and other infrastructure applications.

21% Conductivity Copper-Clad Steel Strand for Turkmenistan: Production, Applications and Selection Guide 1

PROJECT HIGHLIGHT
21% IACS
Copper-Clad Steel Strand

Destination: Turkmenistan

Product: CCS Strand

Conductivity: 21% IACS

Status: Produced & Inspected

What Is 21% Conductivity Copper-Clad Steel Strand?

21% conductivity copper-clad steel strand is a stranded bimetallic conductor consisting of a steel core with a continuous copper cladding layer. The steel provides mechanical strength, while the copper layer provides electrical conductivity and helps protect the steel core.

The term 21% IACS refers to a nominal electrical conductivity level of approximately 21% of the conductivity reference represented by the International Annealed Copper Standard. The appropriate conductivity and conductor construction should always be selected according to the project's electrical and mechanical requirements.

Why Choose 21% IACS Copper-Clad Steel Strand?

CCS strand combines the advantages of two materials to meet electrical and mechanical requirements in demanding infrastructure projects.

01

Strength + Conductivity

The steel core provides mechanical strength while the copper cladding provides the conductive surface.

02

Efficient Material Use

CCS uses a steel core instead of making the entire conductor from copper, which can be advantageous for large infrastructure projects.

03

Mechanical Durability

The steel core helps provide tensile strength for applications where mechanical performance is important.

04

Multiple Applications

CCS strand can be considered for grounding, lightning protection, railway earthing, utility infrastructure and other applications.

Applications of 21% Conductivity CCS Strand

Grounding Systems

Used in grounding systems where electrical performance and mechanical strength are both important.

Lightning Protection

Can be considered for conductive paths in lightning protection and grounding systems.

Railway Earthing

Suitable for evaluation in railway earthing systems according to project requirements.

Cathodic Protection

Can be used in selected cathodic protection applications subject to system design.

What Should Buyers Check When Purchasing CCS Strand?

A professional CCS strand quotation should include more than the price per kilogram. Buyers should confirm the following technical and commercial requirements before production.

Item What Buyers Should Confirm
Conductivity 21% IACS or other required conductivity grade
Conductor Size Overall diameter or required cross-sectional specification
Strand Construction Number of wires, wire diameter and stranding configuration
Mechanical Performance Tensile strength and other project-specific requirements
Testing Electrical, mechanical, dimensional and surface inspection requirements
Standard ASTM, IEC, EN, GB or project-specific specification

21% vs. 30% vs. 40% vs. 70% Conductivity CCS

Higher conductivity is not automatically the best choice. The correct CCS grade depends on electrical requirements, conductor dimensions, mechanical performance and the applicable project standard.

21%

Suitable for applications where conductivity, mechanical strength and cost efficiency need to be balanced.

30%

Provides a higher conductivity level when required by the electrical design.

40%

Considered where a higher electrical conductivity specification is required.

70%

Designed for applications requiring significantly higher electrical conductivity.

KINGYEAR PROJECT CASE

21% IACS CCS Strand for Turkmenistan

KINGYEAR successfully completed the production and quality inspection of a batch of 21% conductivity Copper-Clad Steel Strand for a customer in Turkmenistan.

The finished product was manufactured, inspected and prepared for shipment according to the customer's requirements.

View Original Project

Why This Case Matters for Buyers

International Supply Capability

Demonstrates experience supplying CCS strand for overseas infrastructure projects.

Customized Specification

The product was manufactured according to the customer's required conductivity and application.

Production & Inspection

Production and quality inspection were completed before shipment.

Frequently Asked Questions About 21% CCS Strand

What does 21% IACS mean?

21% IACS indicates a nominal electrical conductivity level of approximately 21% of the conductivity reference represented by the International Annealed Copper Standard.

Is 21% conductivity CCS suitable for grounding?

Copper-clad steel products are used in grounding applications. However, the correct conductivity, diameter and construction must be selected according to the grounding design and applicable standards.

What is the difference between CCS wire and CCS strand?

CCS wire is an individual copper-clad steel element. CCS strand consists of multiple CCS wires stranded together to form a larger conductor.

Is 21% IACS the highest conductivity CCS grade?

No. Copper-clad steel products are available in different conductivity grades. The appropriate grade should be selected based on the electrical and mechanical requirements of the application.

What information should I provide when requesting a CCS strand quotation?

Provide the required conductivity, conductor size, strand construction, application, quantity, applicable standard, destination and required delivery date whenever possible.

Related KINGYEAR Products & Information

Looking for a 21% Conductivity CCS Strand Manufacturer?

Send us your conductivity, strand size, application, quantity and required standard. KINGYEAR can review your requirements and provide a suitable copper-clad steel strand solution.

Get a CCS Strand Quote

prev
0.6/1kV Flexible Power Cable Procurement Guide
recommended for you
GET IN TOUCH WITH Us
Ready to work with us?
Find us here: 
The cable factory from 2007-2018 are mainly for domestic trading and processing to some export tradingcompanies. The average sales amount are about RMB 320,000,000 per year. For cables oversea market, From last may till now we have expanded our market to Bolivia, Peru, Dominican, Philippines, Vietnam, Thailand, Iraq, Mongolia, Indonesia and some Africa country. 
Customer service
detect