Application:
The Low Smoke Zero Halogen (LSZH) Polyolefin oversheath creates a high safety cable that will not emit toxic fumes and smoke in the event of fire, making it appropriate for installations such as buildings and public areas where there is a high concentration of people or valuable equipment.
Model No.:RZ1-K Cable
Voltage:0.6/1kV
Conductor:Class 5 flexible copper conducto
Insulation:XLPE (Cross-Linked Polyethylene)
Sheath:LSZH (Low Smoke Zero Halogen)
Brand:KINGYEAR
Standard:IEC 60502/Gost
Place of Origin:China
Package:Exported Wooden Drum
Range of Application:Power Cable
Terms of Payment: L/C, T/T, D/P, PayPal, Western Union, Small-amount payment
Certification:ISO,CE and other certifications.
Production Capacity:30000m/week
For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.
The RZ1-K (AS) Halogen-free CPR cables comply with the construction product classification criteria according to the EU CPR Regulation 305/2011 and EN 50575, being those indicated for fixed installations, protected or unprotected, where low fumes and corrosive gas emission is required in the event of fire, such as public premises, hospitals, school, shopping centres and airports. They are suitable for indoor and outdoor installations.Their flexibility makes them very appropriate in complex and extremely difficult installations. RZ1-K (AS) 0,6/1 kV cables are manufactured with green colored sheath according standard UNE 21123. RZ1-K (AS) 0,6/1 kV cables can be manufactured in other colors according to IEC 60502.
These electrical cables are suitable for the transport and distribution of electrical energy in fixed installations, whether protected or not. Suitable for indoor and outdoor installations, on supports, in the open air, in tubes or buried. Especially suitable for installations in places where low emission of smoke and corrosive gases is required in case of fire, such as in public places.
Advantage
FAQ
Section (mm2) |
Resistance at 20°C (Ohm/km) |
External Diameter (mm) |
Weight (kg/km) |
---|---|---|---|
1x1,5 |
13,3 |
6,48 |
61 |
1x2,5 |
7,98 |
6,85 |
73 |
1x4 |
4,95 |
7,55 |
94 |
1x6 |
3,3 |
8,24 |
117 |
1x10 |
1,91 |
8,96 |
159 |
1x16 |
1,21 |
10,00 |
219 |
1x25 |
0,78 |
12,10 |
328 |
1x35 |
0,554 |
13,21 |
429 |
1x50 |
0,386 |
15,10 |
587 |
1x70 |
0,272 |
17,00 |
787 |
1x95 |
0,206 |
19,70 |
1029 |
1x120 |
0,161 |
21,50 |
1264 |
1x150 |
0,129 |
23,80 |
1559 |
1x185 |
0,106 |
25,80 |
1872 |
1x240 |
0,0801 |
28,90 |
2479 |
1x300 |
0,0641 |
32,20 |
3047 |
2x1,5 |
13,3 |
9,76 |
130 |
2x2,5 |
7,98 |
10,66 |
164 |
2x4 |
4,95 |
11,80 |
220 |
2x6 |
3,3 |
13,00 |
281 |
2x10 |
1,91 |
14,79 |
397 |
2x16 |
1,21 |
17,00 |
561 |
3x1,5 |
13,3 |
10,20 |
154 |
3x2,5 |
7,98 |
11,18 |
193 |
3x4 |
4,95 |
12,60 |
263 |
3x6 |
3,3 |
13,70 |
334 |
3x10 |
1,91 |
15,46 |
477 |
3x16 |
1,21 |
18,00 |
693 |
3x25 |
0,78 |
21,81 |
1038 |
3x35 |
0,554 |
24,60 |
1390 |
4x1,5 |
13,3 |
11,16 |
176 |
4x2,5 |
7,98 |
12,30 |
231 |
4x4 |
4,95 |
13,36 |
303 |
4x6 |
3,3 |
14,88 |
405 |
4x10 |
1,91 |
16,70 |
581 |
4x16 |
1,21 |
19,80 |
867 |
4x25 |
0,78 |
24,75 |
1349 |
4x35 |
0,554 |
27,50 |
1777 |
4x50 |
0,386 |
31,18 |
2484 |
5x1,5 |
13,3 |
11,97 |
205 |
5x2,5 |
7,98 |
13,15 |
269 |
5x4 |
4,95 |
14,50 |
363 |
5x6 |
3,3 |
16,10 |
481 |
5x10 |
1,91 |
18,14 |
697 |
5x16 |
1,21 |
21,50 |
1042 |
5x25 |
0,78 |
26,59 |
1602 |
5x35 |
0,554 |
30,20 |
2164 |
5x50 |
0,386 |
34,84 |
2977 |