Application:
The N2XH cable range are European power cables for low voltage fixed wiring, increasingly preferred by electrical contractors for distributing mains power around industrial buildings across EMEA.
With copper conductors and XLPE insulation, their low smoke zero halogen, flame-retardant non-corrosive (FRNC) outersheath makes them suitable for use where smoke and corrosive gases would pose a risk to human life and sensitive equipment in the event of a fire.
Model No.:N2XH Cable
Voltage:0.6/1kV
Material:Copper
Brand:KINGYEAR
Standard:IEC/ASTM/BS/GBT/DIN
Place of Origin:China
Package:Exported Wooden Drum
Range of Application:Power Cable
Terms of Payment: L/C, T/T, D/P, PayPal, Western Union, Small-amount payment
Certification:ISO,CE and other certifications.
Production Capacity:30000m/week
The N2XH cable has a voltage rating of 600/1000V / 0.6/1kV. Both the N2XH Enhanced (otherwise known as an N2XH Class 2 cable) and N2XH Enhanced Flex (N2XH Class 5 cable) are available in single core and multicores, in core cross-sectional area sizes up to 300mm2.
Depending on the number of cores and core sizing, conductors are either circular or sectoral stranded - in the case of the smaller core sizes on the N2XH Enhanced cable it may also be a Class 1 solid conductor.
N2XH cables are available with Green/Yellow protective conductor (N2XH-J) and without (N2XH-O).
Conductor:
Up to 16mm2: Class 1 solid copper conductor
Above 16mm2 : Class 2 stranded copper conductor
Insulation
XLPE (Cross-Linked Polyethylene)
Sheath
LSZH (Low Smoke Zero Halogen)
KINGYEAR from 2013-2018 are mainly for domestic trading and processing to some export trading companies. The average sales amount are about RMB 320,000,000 per year. For cables oversea market, From last may till now we have expanded our market to Bolivia, Peru, Dominican, Philippines, Vietnam, Thailand, Iraq, Mongolia, Indonesia and some Africa country. With total sales amount over USD10,000,000.
Specifications
Conductor cross-section |
mm2 |
1,5 |
2,5 |
4 |
6 |
10 |
16 |
25 |
35 |
DC conductor resistance at 20°C, maximum |
Ω/km |
12.1 |
7.41 |
4.61 |
3.08 |
1.83 |
1.15 |
0.727 |
0.524 |
Conductor cross-section |
mm2 |
50 |
70 |
95 |
120 |
150 |
185 |
240 |
300 |
DC conductor resistance at 20°C, maximum |
Ω/km |
0.387 |
0.268 |
0.193 |
0.153 |
0.124 |
0.0991 |
0.0754 |
0.0601 |
Operating voltage Uo/U |
0.6/1 kV |
Voltage test |
4 kV rms |
Insulation resistance, minimum |
100 MΩ·km |
Corrosivity of emitted gases per |
PN-EN 60754-1, PN-EN 60754-2, IEC 60754-2 |
pH appr. |
6,8 |
conductivity appr. |
0,4 µS/mm |
Smoke density per |
PN-EN 61034-2, IEC 61034-2 |
minimum light transmittance |
70% |
Advantage
FAQ