For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation
Model No.:HV Power Cable
Material:Copper(Aluminum)/XLPE/PVC
Voltage: Above 35kV
Brand:KINGYEAR
Standard:IEC
Place of Origin:China
Package:Exported Wooden Drum
Range of Application:Overhead Line
Terms of Payment: L/C, T/T, D/P, PayPal, Western Union, Small-amount payment
Certification:ISO,CE and other certifications.
Production Capacity:30000m/week
● Cross-linked PE insulated power cables for rated voltage 110kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 110kV and its Attachments in GB/T 11017, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840.
● Cross-linked PE insulated power cables for rated voltage 220kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 220kV and its Attachments in GB/T 18890, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV and its Attachments in IEC 62067.
● Cross-linked PE insulated power cables for rated voltage 500kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 500kV and its Attachments in GB/T 22078, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV and its Attachments in IEC 62067.
● Cross-linked PE insulated power cables for rated voltage 66kV should perform The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840.
Cable Construction
1-The property of cable conductor is in accordance with the rules of GB/T 3956-2008. The cross-section below 800mm2 should be tight round winding conductor; above 1000mm2 should be segmentation conductor construction.
2-Inner shield adopt the cross-linked semi-conductive shield materials to extrude over the conduct extremely smoothly.
3-Insulation should adopt the extremely clean XLPE insulation materials, and triple extrude with outer shield tightly bonded.
4-Outer shield should adopt cross-linked shield materials o extrude over insulation extremely smooth.
5-Vertical water blocking layer and buffer layer should adopt semi-conductive water-proof tapes with strong capacity of water-proof to wrap between the outer shields and vertical water-proof layer.
6-Vertical water-proof layer should adopt the al-plastic composites and iron jack should adopt corrugated aluminum or lead sheath, which can meet the capacity and screen of short circuit.
7-Protection layer and corrosion resistance layer make sure the effective protection for the corrugated aluminum jack or lead sheath.
KINGYEAR from 2013-2018 are mainly for domestic trading and processing to some export trading companies. The average sales amount are about RMB 320,000,000 per year. For cables oversea market, From last may till now we have expanded our market to Bolivia, Peru, Dominican, Philippines, Vietnam, Thailand, Iraq, Mongolia, Indonesia and some Africa country. With total sales amount over USD10,000,000.
Specifications
Single Core Cable - 6/10kV and 8.7/15kV
No. of cores and nominal cross section |
Thickness of insulation |
Cross section of Screen |
Thickness of Sheath |
Approx. overall Diameter |
Approx. weight |
Max. DC resistance of conductor(20ºC) |
Current carrying capacity |
|
(mm2) |
(mm) |
(mm2) |
(mm) |
(mm) |
(kg/km) |
(Ω/km) |
In air |
In ground (A) |
6/10kV |
||||||||
1x25/16 |
3.4 |
16 |
1.8 |
21.8 |
568 |
1.20 |
120 |
115 |
1x35/16 |
3.4 |
16 |
1.8 |
22.9 |
619 |
0.868 |
153 |
145 |
1x50/16 |
3.4 |
16 |
1.8 |
24.0 |
684 |
0.641 |
183 |
171 |
1x70/16 |
3.4 |
16 |
1.8 |
25.7 |
782 |
0.443 |
228 |
208 |
1x95/16 |
3.4 |
16 |
1.8 |
27.2 |
891 |
0.320 |
278 |
248 |
1x120/16 |
3.4 |
16 |
1.8 |
28.7 |
992 |
0.253 |
321 |
283 |
1x150/25 |
3.4 |
25 |
1.8 |
30.2 |
1184 |
0.206 |
364 |
315 |
1x185/25 |
3.4 |
25 |
1.9 |
32.0 |
1340 |
0.164 |
418 |
357 |
1x240/25 |
3.4 |
25 |
2.0 |
34.7 |
1560 |
0.125 |
494 |
413 |
1x300/25 |
3.4 |
25 |
2.1 |
36.9 |
1790 |
0.100 |
568 |
466 |
1x400/35 |
3.4 |
35 |
2.2 |
40.2 |
2200 |
0.0778 |
660 |
529 |
1x500/35 |
3.4 |
35 |
2.3 |
44.1 |
2590 |
0.0605 |
767 |
602 |
8.7/15kV |
||||||||
1x25/16 |
4.5 |
16 |
1.8 |
23.8 |
648 |
1.20 |
100 |
105 |
1x35/16 |
4.5 |
16 |
1.8 |
24.8 |
703 |
0.868 |
153 |
145 |
1x50/16 |
4.5 |
16 |
1.8 |
26.1 |
772 |
0.641 |
183 |
172 |
1x70/16 |
4.5 |
16 |
1.8 |
27.8 |
876 |
0.443 |
228 |
210 |
1x95/16 |
4.5 |
16 |
1.8 |
29.4 |
990 |
0.320 |
278 |
250 |
1x120/16 |
4.5 |
16 |
1.9 |
31.0 |
1110 |
0.253 |
321 |
285 |
1x150/25 |
4.5 |
25 |
1.9 |
32.5 |
1308 |
0.206 |
364 |
318 |
1x185/25 |
4.5 |
25 |
2.0 |
34.4 |
1472 |
0.164 |
418 |
360 |
1x240/25 |
4.5 |
25 |
2.1 |
36.8 |
1704 |
0.125 |
494 |
418 |
1x300/25 |
4.5 |
25 |
2.1 |
39.0 |
1928 |
0.100 |
568 |
471 |
1x400/35 |
4.5 |
35 |
2.3 |
42.4 |
2371 |
0.0778 |
660 |
535 |
1x500/35 |
4.5 |
35 |
2.3 |
45.3 |
2754 |
0.0605 |
767 |
608 |
Single Core Cable - 12/20kV and 18/30kV
No. of cores and nominal cross section |
Thickness of insulation |
Cross section of screen |
Thickness of sheath |
Approx. overall diameter |
Approx. weight |
Max. DC resistance of conductor(20ºC) |
Current carrying capacity |
|
(mm2) |
(mm) |
(mm2) |
(mm) |
(mm) |
(kg/km) |
(Ω/km) |
In air (A) |
In ground (A) |
12/20kV |
||||||||
1x35/16 |
5.5 |
16 |
1.8 |
26.9 |
778 |
0.868 |
175 |
115 |
1x50/16 |
5.5 |
16 |
1.8 |
28.2 |
851 |
0.641 |
210 |
140 |
1x70/16 |
5.5 |
16 |
1.9 |
30.1 |
974 |
0.443 |
255 |
170 |
1x95/16 |
5.5 |
16 |
1.9 |
31.7 |
1094 |
0.320 |
310 |
205 |
1x120/16 |
5.5 |
16 |
2.0 |
33.3 |
1219 |
0.253 |
345 |
240 |
1x150/25 |
5.5 |
25 |
2.0 |
34.8 |
1422 |
0.206 |
400 |
270 |
1x185/25 |
5.5 |
25 |
2.1 |
36.7 |
1593 |
0.164 |
455 |
310 |
1x240/25 |
5.5 |
25 |
2.1 |
38.9 |
1815 |
0.125 |
530 |
360 |
1x300/25 |
5.5 |
25 |
2.2 |
41.3 |
2065 |
0.100 |
605 |
420 |
1x400/35 |
5.5 |
35 |
2.3 |
44.5 |
2499 |
0.0778 |
700 |
485 |
1x500/35 |
5.5 |
35 |
2.4 |
47.6 |
2912 |
0.0605 |
795 |
535 |
18/30kV |
||||||||
1x35/16 |
8.0 |
16 |
2.0 |
32.2 |
1042 |
0.868 |
185 |
134 |
1x50/16 |
8.0 |
16 |
2.0 |
33.4 |
1138 |
0.641 |
222 |
157 |
1x70/16 |
8.0 |
16 |
2.1 |
35.3 |
1276 |
0.443 |
278 |
192 |
1x95/16 |
8.0 |
16 |
2.1 |
37.1 |
1426 |
0.320 |
338 |
229 |
1x120/16 |
8.0 |
16 |
2.2 |
38.6 |
1559 |
0.253 |
391 |
260 |
1x150/25 |
8.0 |
25 |
2.2 |
40.6 |
1792 |
0.206 |
440 |
288 |
1x185/25 |
8.0 |
25 |
2.3 |
42.3 |
1971 |
0.164 |
504 |
324 |
1x240/25 |
8.0 |
25 |
2.3 |
44.8 |
2234 |
0.125 |
593 |
373 |
1x300/25 |
8.0 |
25 |
2.4 |
47.2 |
2497 |
0.100 |
677 |
419 |
1x400/35 |
8.0 |
35 |
2.5 |
50.4 |
2967 |
0.0778 |
769 |
466 |
1x500/35 |
8.0 |
35 |
2.6 |
53.3 |
3417 |
0.0605 |
872 |
573 |
Advantage
FAQ